Stainless and carbon steel flanges for hyperscale data center cooling piping
Weld neck, slip-on, blind and lap joint flanges in 316L, 304L, A105 and A350 LF2 for the chilled water, condenser water and liquid cooling piping of hyperscale, colocation and enterprise data centers, made to ASME B16.5, B16.47, EN 1092-1 and AWWA C207 and C228 and forged, machined and tested at our works in Gujarat, India, with an EN 10204 3.1 certificate for every heat.
- ISO 9001:2015, TÜV NORD
- PED 2014/68/EU material manufacturer
- EN 10204 3.1 with every order

Where our flanges sit in a liquid-cooled data center
Supply, cooler water to the racksReturn, warmer water to the plant
- Heat rejectionCooling towers, dry coolers, condenser water pumpsA105, A350 LF2
AWWA C207, B16.5 Class 150
Flat face to cast iron pumps - Chiller plantChillers, primary and secondary pumps, headersA105, 304L, 316L
B16.5, B16.47, PN16
Weld neck, slip-on, blind - Facility waterMains from the plant to the white space and CDUsA105 or 304L/316L
B16.5 Class 150, EN 1092-1
4 to 48 in mains - Coolant distribution unitHeat exchanger between facility water and the IT coolant316L, 304L
B16.5 Class 150, PN16
Pickled and passivated - Technology coolingRow manifolds to racks and cold plates316L stainless
Class 150 WN, SO, lap joint
Clean, PMI checked
Flanges by material, standard and type
Every flange is made to your line list, so one package can cover the plant room, the CDU skids and the white space.

Stainless steel flanges
304L and 316L for CDUs, TCS loops and stainless mains. Pickled and passivated on request.
ASTM A182 F304L, F316L
Carbon steel flanges
A105 and A350 LF2 for chilled water, condenser water and facility water mains.
ASTM A105, A350 LF2, A516-70ASME B16.5
NPS 1/2 to 24, Class 150 and 300. The default for data center mechanical piping.
Class 150, RF, FFASME B16.47
Series A and B weld neck and blind flanges for headers above 24 inches.
Series A, Series BEN 1092-1
PN 6 to PN 100 flanges for European data centers, with a PDF drawing for every size.
PN 6 to 100, Types 01, 05, 11AWWA C207
Steel ring, hub and blind flanges for large chilled and condenser water mains.
Ring, hub and blind, flat faceAWWA C228
Stainless ring slip-on and blind flanges for large stainless water mains.
Ring slip-on and blind, flat faceLap joint and stub ends
Only the 316L stub end is wetted; the loose flange rotates for easy alignment.
B16.9, MSS SP-43Stainless flanges that arrive ready for a clean loop
Cold plates on direct-to-chip servers will not pass a particle much above 50 microns, so the secondary loop has to start clean and stay clean. The Open Compute Project's pre-commissioning guide calls for stainless pipework of at least grade 304, delivered with internal surfaces treated to ASTM A380.
- Pickled and passivated to ASTM A380 and A967 when you specify it, to remove free iron and restore the passive chromium oxide layer.
- 100% positive material identification on our Bruker PMI analyser, recorded on the certificate.
- Intergranular corrosion testing to ASTM A262 Practice E on request, shown on the MTC.
- Heat number stamped before machining, so every flange traces back to its melt.
Flanges for the technology cooling systemPickling and passivation explained

We forge, machine and test under one roof
Bar is cut, heated and forged on our 1.25-metric-ton hammer, machined on CNC and conventional lathes, then tested in our own lab before it is marked and packed for export.
Play film 4:20




- Site area
- 45,000 sq ft
- Founded
- 2000
- Forging hammer
- 1.25 MT
- Hydraulic presses
- 300 and 150 MT
- People
- 100+
Flanges by cooling system
Each loop has its own fluid, pressure and cleanliness rules, so each has its own flange specification.

Chilled water systems
Plant rooms, headers and facility water mains. A105 and stainless, Class 150 and PN16.
CHW, FWS
Condenser water and cooling towers
Large, low pressure mains to towers and dry coolers. A105, LF2 and AWWA C207.
CW, heat rejection
Coolant distribution units
Stainless flanges and stub ends for CDU builders and skid fabricators.
CDU, FWS to TCS
Technology cooling system (TCS)
The clean secondary loop to the racks. 316L, pickled and passivated, crevice-free joints.
TCS, SFN, DLCFlanges for hyperscale data centers and AI campusesCDU to rack piping, with a sample BOQFlanges for data center projects in India: Mumbai, Chennai, Hyderabad and more
Technical notes on data center piping
- Direct-to-chip coolingCold plates, manifolds and CDUs, flow per kW, and which joints in a direct-to-chip system are flanged.
- CDU to rack piping and BOQManifold connectivity from CDU to rack, sized for 142 kW racks, with a sample bill of quantities.
- FWS vs TCSThe two water loops of a liquid-cooled data center and what each means for materials and flanges.
- Pressure class selectionClass 150 or 300, PN16 or PN25: static head, pump head, surge and test pressure, with a worked example.
- Flange gasketsEPDM, PTFE and CNAF for water and glycol loops: material, shape, thickness and face finish.
- ASTM A380 and A967 passivationA380 vs A967, nitric and citric treatments, tests and order wording for TCS loops.
Technical library
- Catalog 2026, 8 pages: the range with sections, sizes and classes, materials, standards, quality steps and certificates, and a 2-page flyer.
- Flange handbook, 18 pages: dimensions, bolting and weights for every ASME B16.5 class and every EN 1092-1 PN.
- Material datasheets for F304/F304L, F316/F316L, A105 and A350 LF2: chemistry, mechanical properties and heat treatment.
- 23 technical guides as white papers, each with its sources.
- 892 flange drawings, one for every size, class and type we list, with the bore for every schedule and the weight in carbon and stainless steel.
- 3D models of the same flanges with our marking, to turn on screen or save as STEP or STL.
- Certificates for your vendor file and a sample mill test certificate.
Certifications
Certificates for your vendor file, plus a sample mill test certificate. NORSOK M-650 for duplex and ISO 29001 for the petroleum industries are on the quality page.

ISO 9001:2015